Vented Workstations

Vented Workstations

Flow Sciences Vented Workstations Data Sheet
Click here to view the manufacturer's data sheet.

Vented Workstations

Designed for:

  • Tissue Trimming
  • Animal Necropsy
  • Cover Slipping
  • Staining
  • Titrating
  • Transfers
  • Pipetting
  • Chemical Transfers
  • Slide Preps
  • Pharmacy Compounding

Description:

Flow Sciences' Vented Containment Workstation provides a safe contained working environment for a variety of standard bench-focused lab procedures. The increased angle at the front of the Workstation allows close-up work without sacrificing safety or comfort. Each workstation offers multiple user options and tremendous laboratory flexibility. The workstation can be utilized as a tissue-trimming site. As the laboratory mission changes, it can easily be moved to another location and operate as a pipetting center. Units can also be customized with sink insert.

Flow Sciences offers a variety of filter options to meet specific containment needs. Systems are available with HEPA, Organic or Aldehyde filtration. Filters can be combined using a Dual Fan/Filter Housing.

The Flow Sciences' Vented Workstations meet and exceed the ASHRAE 110 standard for containment.

Features:

  • Enclosure constructed of 3/8" acrylic.
  • Chemically resistant phenolic resin base.
  • Dished to contain spills.
  • Base available in white or black.
  • Air plenums mounted on rear of hood.
  • Filter air using the FSI Fan Filter Housing and then connect to house exhaust via a thimble connection.
  • Filter air using the FSI Fan Filter Housing and then recirculate back into the lab.
  • Enclosure can connect directly to house exhaust.
  • Multiple filtering options available including Bagout HEPA with 99.99% efficiency and a variety of Carbon filters in single or dual filtration configurations.
  • Angled front of enclosure allows safe up-close work.
  • Maximum personnel protection maintained without sacrificing worker comfort.
  • Aerodynamically designed air foils equipped with alarm sensor.
  • Units come standard with Face Velocity Alarm.
  • All clear models available for increased visibility .

Units must be certified by a safety professional before beginning any work within the hood.

Click HERE to contact us for more information.



Flowsciences Microscope Workstation

Microscope Workstations

Flow Sciences Microscope Workstations Data Sheet
Click here to view the manufacturer's data sheet.

Microscope Workstations

Designed for:

  • Each enclosure is customized to meet microscope dimensions
  • Provides turbulence-free environment that will not disrupt samples
  • Ergonomically designed for worker comfort

Description:

Flow Sciences' Vented Microscope Workstations offer maximum protection while handling delicate samples in the laboratory. Enclosures are designed with a cutout that accommodates microscope dimensions. Units provide a safe, turbulence-free work environment while protecting personnel from exposure to harmful substances.

Although there are standard microscope enclosures, quite often it is necessary to customize these units to accommodate the equipment and/or application needs. Flow Sciences can provide a cardboard mock-up of the desired enclosure to help alleviate any clearance or access issues.

Features:

  • Enclosure constructed of 3/8" acrylic.
  • Chemically resistant phenolic resin base.
  • Dished to contain spills.
  • Base available in white or black.
  • Air plenums mounted on rear of hood.
  • Filter air using the FSI Fan Filter Housing and then connect to house exhaust via a thimble connection.
  • Filter air using the FSI Fan Filter Housing and then recirculate back into the lab.
  • Enclosure can connect directly to house exhaust.
  • Multiple filtering options available including Bagout HEPA with 99.99% efficiency and a variety of Carbon filters in single or dual filtration configurations.
  • Angled front of enclosure allows safe up-close work.
  • Maximum personnel protection maintained without sacrificing worker comfort.
  • Aerodynamically designed air foils equipped with alarm sensor.
  • Units come standard with Face Velocity Alarm .

Units must be certified by a safety professional before beginning any work within the hood.

Click HERE to contact us for more information.



Flowsciences Anesthetic Workstation

Anesthetic Workstations

Flow Sciences Anasthetic Workstations Data Sheet
Click here to view the manufacturer's data sheet.

Anesthetic Workstations

For the anesthetizing of lab animals

Provides effective containment of:

  • Anesthetic gases.
  • Animal dander.
  • Bacterial and viral agents.
  • Face Cover permits effective containment without rousing anesthetized animals.
  • Enclosure provides outside access to anesthetizing device for added protection.
  • Designed with internal shelf to house anesthetizing device.

Description:

Flow Sciences' Vented Anesthetic Containment Enclosure provides a safe work environment for the anesthetizing of animals in the laboratory. Using the same design criteria behind the VBSE™, each enclosure is manufactured with a draft shield and internal shelf to house an anesthetizing device.

Features:

  • Enclosure constructed of 3/8" acrylic.
  • Chemically resistant phenolic resin base.
  • Dished to contain spills.
  • Black Base for easy powder detection.
  • White Base available.
  • Air plenums mounted on rear of hood.
  • Filter air using the FSI Fan Filter Housing and then connect to house exhaust via a thimble connection.
  • Filter air using the FSI Fan Filter Housing and then recirculate back into the lab.
  • Enclosure can connect directly to house exhaust.
  • Multiple filtering options available including Bagout HEPA with 99.99% efficiency and a variety of Carbon filters in single or dual filtration configurations.
  • Angled front of enclosure allows safe up-close work.
  • Maximum personnel protection maintained without sacrificing worker comfort.
  • Aerodynamically designed air foils equipped with alarm sensor.
  • Each system comes standard with a Face Velocity Alarm.

Units must be certified by a safety professional before beginning any work within the hood.

Click HERE to contact us for more information.

Featured Product